Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Transmitter Synchro
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Standard round a
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
0.5000 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.6300 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
0.7500 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.0620 inches
Undercut Diameter:
0.6910 inches
Undercut Width:
0.0620 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.0900 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.3350 inches single shaft
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
Err-090
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
Maximum Tempurature Rise:
30.0 degrees celsius
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
8
MRC:
The value of the primary excitation voltage for which the rotor is rated,expressed in volts.AJSR
Rotor Input Voltage Rating In Volts:
115.0
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The value of the primary excitation current for which the rotor is rated,with stator /secondary/ circuit open.AJST
Rotor Input Current Rating:
29.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the rotor is rated.AJSV
Rotor Input Electrical Power Rating:
800.0 allqjaa3.500 finished-chamfered
MRC:
The resistance /r/ part of the rotor impedance with the stator open /zro/,expressed in ohms.AJSW
Zro Resistance In Ohms:
950.00
MRC:
The resistance /r/ part of the stator impedance with the rotor open /zso/,expressed in ohms.AJSY
Zso Resistance In Ohms:
10.00
MRC:
The resistance /r/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.AJTA
Zrs Resistance In Ohms:
1550.00
MRC:
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.AJTS
Rotor Dc Resistance In Ohms:
700.00
MRC:
The opposition that the stator offers to the flow of direct current,expressed in ohms.AJTT
Stator Dc Resistance In Ohms:
10.40
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
11.000 input to output
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
50.00 output
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
75.00
MRC:
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.AJVL
Electrical Error Angular Range In Minutes:
-7.0/+7.0
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at minus 55 degrees celsius.AJVS
Actuator Friction Torque At Minus 55 Deg Celsius:
15.0 centimeter-grams
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at plus 25 degrees celsius.AJVT
Actuator Friction Torque At Plus 25 Deg Celsius:
4.0 centimeter-grams
MRC:
The measurement taken from the bearing face to the point on the shaft where the weight /load/ is applied.AJWE
Shaft Radial Play Test Point:
0.125 inches
MRC:
The maximum shaft displacement perpendicular to the shaft axis due to reversal of a specified force applied perpendicular to the shaft axis,and measured at a specified distance from the front surface of the unit.AJWG
Shaft Maximum Radial Play:
0.0008 inches
MRC:
The axial shaft displacement due to reversal of a specified axial force,measured at the end of the shaft.AJWH
Shaft End Play:
0.0015 inches
MRC:
A measurement of the longest dimension of a pilot,in distinction from width.AJWQ
Pilot Length:
0.0400 inches
Mounting Surface To Terminal End Distance:
1.2400 inches
MRC:
The eccentricity of the shaft diameter with respect to the rotational axis of the shaft,measured at a specified distance from the end of the shaft,when the body of the item is held fixed and the shaft is rotated.AJXB
Shaft Maximum Runout:
0.0010 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
MRC:
The reactance (x) part of the rotor impedance with the stator open (zro).CQXQ
Plus J Zro Reactance In Ohms:
3850.00
Shaft Slot Depth:
0.0250 inches single shaft
MRC:
The reactance (x) part of the stator impedance with the rotor open (zso),expressed in ohms.CRGZ
Plus J Zso Reactance In Ohms:
36.00
Shaft Slot Width:
0.0300 inches single shaft
MRC:
The reactance /x/ part of the rotor impedance with the stator shorted /zrs/,expressed in ohms.CRKL
Plus J Zrs Reactance In Ohms:
420.00
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, slotted single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
0.1025 stator to rotor
MRC:
The force (load) applied perpendicular to the shaft axis to determine radial play.CWXK
Shaft Radial Play Determining Weight:
4.0 ounces
MRC:
The force (load) applied parallel to the shaft axis to determine end play.CWYF
Shaft End Play Determining Weight:
8.0 ounces
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead