Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Humidity range: 20.0% to 98.0% indry bulb range of p20.0 deg. C. To p85.0 deg. C.; water inpu (humidity models) : neglpgible consumption; power requirements: 100, 000 to 200, 000 ft.
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Environmental Testing Chamber
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
123.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
91.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
77.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
48.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
48.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
48.000 inches
MRC:
The form of assembly in which the item is supplied,whether completely assembled or specifying a degree of assembly which inherently describes the presence of a space saving feature.AFPM
Assembly Form:
Assembled
MRC:
The means provided to close the opening of the item.AFPP
Closure Method:
Hinged cover
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Instrumentation and control panel1; fan 1; motor, external 1; nichrome heater 1; vapor proof interior light 1; thermal pane viewing window 1; pump, vacuum 1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
230.0 volts
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
-73.0 to 177.0
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Mechanical
MRC:
An indication of whether or not a door(s) is provided.BHJQ
Door:
Provided
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
The element,compound,or mixture of which the outer door is fabricated,excluding any surface treatment.BQMP
Outer Door Material:
Steel
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Included
MRC:
Indicates the type of environmental chamber.CWZY
Environmental Chamber Type:
Altitude and humidity and temperature
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Blue
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel