Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Circuit Breaker				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rectangular dimensional envelope					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.260 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.200 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.250 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.172 inches 					
				 
							
					
						MRC:
						A designation that describes the basic electrical configuration of a switch.AEGJ
					 
					
						Switch Contact Arrangement:
					
					
						Single pole,  double throw					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						1					
				 
							
					
						MRC:
						The means of quenching an arc.APNQ
					 
					
						Arc Quenching Method:
					
					
						Air					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 unthreaded hole					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						25.0 amperes ac single location and 25.0 amperes dc single location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						115.0 ac single location and 28.0 dc single location					
				 
							
					
						MRC:
						Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
					 
					
						Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
					
					
						3600.0 ac single location and 3600.0 dc single location					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent single location					
				 
							
					
						MRC:
						The means by which the trip mechanism is released.CPRJ
					 
					
						Trip Release Method:
					
					
						Thermal single location					
				 
							
					
						MRC:
						Denotes the type of trip release action.CPRL
					 
					
						Trip Release Characteristic:
					
					
						Time delay single location					
				 
							
					
						MRC:
						The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
					 
					
						Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
					
					
						150.0 single location					
				 
							
					
						MRC:
						The means provided to reposition the mechanism so that the device is ready to function.CPRQ
					 
					
						Reset Method:
					
					
						Electric					
				 
							
					
						MRC:
						Indicates the type of mechanism provided for tripping main contacts.CPRR
					 
					
						Main Contact Tripping Mechanism Type:
					
					
						Trip free					
				 
							
					
						MRC:
						The function for which the auxiliary switch is designed and the number provided.CPRZ
					 
					
						Auxiliary Switch Function And Quantity:
					
					
						1 alarm					
				 
							
					
						MRC:
						The basic internal electrical configuration of the trip mechanism.CPSM
					 
					
						Internal Trip Release Configuration:
					
					
						Series trip single location					
				 
							
					
						MRC:
						Indicates the location of the switch in relation to its designated position.CQSM
					 
					
						Switch Location And Position Designation:
					
					
						Internal at pole one					
				 
							
					
						MRC:
						The voltage,expressed in volts,and current type for which the reset actuator is rated.CQTL
					 
					
						Reset Actuator Voltage Rating And Type In Volts:
					
					
						115.0 ac					
				 
							
					
						MRC:
						The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
					 
					
						Trip Delay Time In Seconds Per Rated Continuous Current:
					
					
						15.000  at 200 pct single location and 50.000  at 200 pct single location					
				 
							
					
						MRC:
						Indicates the type of protection for which the inclosure is designed.CQXF
					 
					
						Inclosure Protection Type For Which Designed:
					
					
						Dustproof					
				 
							
					
						MRC:
						The temperature of the medium surrounding the trip release at which it can be operated continuously.CRCF
					 
					
						Trip Release Ambient Tempurature Rating:
					
					
						75.0 degrees fahrenheit  single location					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the switch.CRTK
					 
					
						Switch Terminal Type:
					
					
						Tab,  solder lug					
				 
							
					
						MRC:
						The amount of current,expressed in amperes,and the type for which the switch is rated.CSSX
					 
					
						Switch Current Rating And Type In Amps:
					
					
						3.0 ac and 3.0 dc					
				 
							
					
						MRC:
						The voltage,expressed in volts,and current type for which the switch is rated.CSWP
					 
					
						Switch Voltage Rating And Type In Volts:
					
					
						115.0 ac and 28.0 dc					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						400.0 single location					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						81349-mil-c-83383 specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 threaded stud					
				 
							
					
						MRC:
						The document designator of the specification or standard which established the item of supply.ZZZK
					 
					
						Specification Data:
					
					
						81349-mil-c-83383/2 government specification