Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						0.770 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.135 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Dustproof					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 plug-in terminal single mounting facility					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
					 
					
						Nonpile-up Main Contact Arrangement:
					
					
						1 pole,  single throw,  normally open,  momentary action					
				 
							
					
						MRC:
						The required current value,applied to the energizing element,at which the switching mechanism or actuator element must have assumed a fully operated position.CRPQ
					 
					
						Operating Current Rating And Type:
					
					
						9.5 milliamperes dc single winding					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						500.0 milliamperes dc resistive load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						200.0 dc					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						4 pin all functions