Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply Control
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Cadmium, qq-p-416, type 2, class 3 and paint
MRC:
The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
Connector Manufacturer Code:
71468
MRC:
The identifying part number assigned to the electrical connector receptacle.AEEF
Connector Manufacturer Part Number:
Am3108a14s4c
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+50.0 degrees celsius
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
125.0 ac and 28.0 dc and 48.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
3.0 and 12.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
Ac input 105 to 125 volts, dc output no 1 38 to 48 volts, dcoutput no. 2 20 to 28 volts both variable
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Deck and flush panel
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
3 quick disconnect, female
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
16.000 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
20.000 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
22.000 inches
MRC:
The intelligence data the item is capable of handling.CKQY
Intelligence Data Handling Capability:
Power source transmitting manual
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Transmitting meter movement
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0