Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Control Motor
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
1.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
0.937 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1417 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The number of teeth included on the item.AJLA
Teeth Quantity:
15 single end
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 clamp collar
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
The current rating of the control field,expressed in amperes.BFMJ
Control Field Current Rating In Amps:
0.036
MRC:
The impedance rating of the control field,expressed in ohms.BFMK
Control Field Impedance Rating In Ohms:
1375.0
MRC:
Indicates the type of winding(s) of the control field.BFML
Control Field Winding Type:
Single winding
Full Tooth Length:
0.1880 inches single end
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Locked rotor
MRC:
Indicates the torque rating,and its type.BKPH
Torque Rating And Type:
0.2 inch-ounces stalled
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
57.5 ac
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.188 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-55.0 operating degrees celsius and 125.0 operating degrees celsius
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.018 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A17 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead