Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						672-0386-010					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Transformer				
			 
			
										
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						2.125 inches  single mounting facility single center group					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						1.750 inches  single mounting facility single center group					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						47.0 hertz  single component and 420.0 hertz  single component					
				 
							
					
						MRC:
						The relationship of the phase input to the phase output of an alternating current.ACZC
					 
					
						Input-output Phase Relationship:
					
					
						Single phase to single phase single component					
				 
							
					
						MRC:
						The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
					 
					
						Winding Shielding Method:
					
					
						Internal shield grounded to core single component					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.750 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						2.375 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						3.812 inches 					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						4 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Threaded stud single group					
				 
							
					
						MRC:
						The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
					 
					
						Winding Function And Quantity:
					
					
						1 primary single component and 2 secondary single component					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						32 single group					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.138 inches single group					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						13.00 ac volts  single component 2nd secondary52.00 ac volts  single component 1st secondary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						115.00 ac volts  single component single primary13.00 ac volts  single component 2nd secondary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						52.00 ac volts  single component 1st secondary					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unc single group					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 turret