Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						672-0535-020					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Primary terminal grounded to core
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Transformer				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Moisture resistant and vibration resistant					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						50.0 kilohertz  single component					
				 
							
					
						MRC:
						The relationship of the phase input to the phase output of an alternating current.ACZC
					 
					
						Input-output Phase Relationship:
					
					
						Single phase to single phase single component					
				 
							
					
						MRC:
						The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
					 
					
						Winding Shielding Method:
					
					
						Core grounded single component					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						0.560 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.765 inches 					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Terminal single group					
				 
							
					
						MRC:
						The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
					 
					
						Winding Function And Quantity:
					
					
						1 primary single component and 1 secondary single component					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						200.0 milliamperes dc  single component single secondary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						14.00 dc volts  single component single secondary					
				 
							
					
						MRC:
						The value/s/ of the operating voltage applied to the winding.CWJS
					 
					
						Winding Operating Voltage:
					
					
						160.00 dc volts  single component single primary					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						13499-672-0535 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						5 pin