Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
2 adapters
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Cable Assembly
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
10.000 feet
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.575 inches
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector plug 1st end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector receptacle 2nd end all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
10
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
20 awg all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
Ms3106b28-12p 1st end all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
Ms3106b28-12s 2nd end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
96906 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
96906 both ends all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic 1st position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic 1st position primary insulation all conductors