Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.437 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.530 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.781 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Peace shield a
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac volts 3rd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
220.0 ac volts 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 ac volts 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
100.0 ac volts 4th alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-10.0 dc volts 2nd power output and 10.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-100.0 dc volts 1st power output and 100.0 dc volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
48.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-0.1/+55.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
On-off switch-indicator and dc ammeter and remote error sensing capability and function switch and current regulator circuit and voltage adjustment and dc voltmeter and over voltage protector and remote programming
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc amperes single power output and 0.5 dc amperes single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Wire lead single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection