Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Controller, ac magnetic size 2
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Motor Controller
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Dripproof and watertight and submersible and hazardous location, class i, group d, nema type 7 and moisture resistant
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.380 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.060 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
440.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Starter, motor
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
1
MRC:
A designation indicating the size by which the item is commercially known and/or identified.AJXE
Size Designator:
2
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
4 each 17/32 inch diameter holes for 1/2 inch mounting bolts through enclosure wall
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
25.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
440.0 ac
MRC:
The value of current for which the fuse is rated,expressed in amperes.ANDG
Fuse Current Rating In Amps:
10.0
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Undervoltage and overload
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof and splash proof and submersible
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Designed per nema std
MRC:
The ampere size designation for special design type items which are rated in ampere size rather than horsepower.ANRH
Amp Size Rating:
45.0
MRC:
An indication of the various functional switching positions.ANRK
Switch Functional Positions:
Start and stop and reset and emergency run and emergency stop
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Accessory location internal and circuit protection fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Enclosure & components are shockproof, grade a, class 1 of mil-s-901; contactor n894; across-the-line operation
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0