Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Control temp indicating 125/250v ac 15 amps 2.5x3.75" alum case
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Indicating Temperature Control
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Paint
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-210.0/+280.0 degrees fahrenheit
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately delicate
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
125.0 ac or 250.0 ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
6530-01-120-2658
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
15.0
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Back corner
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Panel
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
3 wire lead
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
3.500 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
3.750 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
1.875 inches
MRC:
Indicates the type and location of the sensing element.CKRD
Sensing Element Type And Location:
Bulb remote
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Capiliary tube 0.062 in. Diameter by 32.0 in. Lg; bulb sensing element 0.375 in. By 11.5 in. Lg with an o-ring 0.437 in. Od by 0.062 in. Thk; total length of capiliary tube and sensing element 43.500 in; panel mtg clamp provided
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Use to control temperature increments of 2 degrees farenheit
MRC:
The controlling activity and identification of a document used in lieu of a specification in the procurement of an item of supply.ZZZP
Purchase Description Identification:
21518-68053