Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
6999ed1026-2
Informationen zum Teil
Item must comply with requirements of defense supply center columbus production standard no. Lo4505
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Diode Semiconductor Device
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Metal
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.578 inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud
MRC:
The overall measurement from one flatted surface to the opposite flatted surface.CCDG
Overall Width Across Flats:
1.250 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Zzzy
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Silicon
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
800.0 reverse voltage, instantaneous and 1000.0 repetitive peak reverse voltage and 1200.0 nonrepetitive peak reverse voltage
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
395.00 amperes forward current, average of standard range
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
150.0 degrees celsius junction
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
27192-6999ed1026 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 threaded stud and 1 insulated wire lead w/terminal lug
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Areference number differentiating material will be in accordance with naval inventory control point activity hx quality control. Manufacturing and testing specifications available at the dla icp