Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Calibrated timing dial front screw terminals 8-32 truss head screws, potted coil, ambient temp range of m67 degrees f to p165 degrees f.
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Relay-switch				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.250 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.760 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.090 inches 					
				 
							
					
						MRC:
						Indicates the type of switch included in the item.AEEA
					 
					
						Switch Type:
					
					
						Pressure					
				 
							
					
						MRC:
						The pattern or arrangement that describes the mounting configuration of the item.ALGC
					 
					
						Mounting Configuration:
					
					
						Vertical mounting, front or back, or horizontal mounting, 4 tapped holes on back plate					
				 
							
					
						MRC:
						Indicates the type of action provided.AMWM
					 
					
						Action Type:
					
					
						Time delay					
				 
							
					
						MRC:
						Indicates the type of relay/s/ provided.APCL
					 
					
						Relay Type:
					
					
						Time delay					
				 
							
					
						MRC:
						Indicates the type of current used with the contact/s/.APFX
					 
					
						Contact Current Type:
					
					
						Ac and dc					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
					 
					
						Maximum Voltage Rating In Volts:
					
					
						480.0					
				 
							
					
						MRC:
						The amount of current at maximum rated voltage for which the item is designed.APGW
					 
					
						Current Rating At Maximum Rated Voltage:
					
					
						10.0 amperes resistive					
				 
							
					
						MRC:
						The maximum amount of current for which the item is designed,expressed in amperes.APGX
					 
					
						Maximum Current Rating In Amps:
					
					
						20.0 resistive					
				 
							
					
						MRC:
						The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
					 
					
						Voltage Rating At Maximum Rated Current:
					
					
						240.0 volts					
				 
							
					
						MRC:
						Indicates the type of current for which the coil is designed.APGZ
					 
					
						Coil Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						The amount of operating voltage,expressed in volts.APHA
					 
					
						Operating Voltage In Volts:
					
					
						Between 200.0 and 300.0 					
				 
							
					
						MRC:
						The amount of time required for tripping the item,expressed in seconds.APMG
					 
					
						Tripping Time In Seconds:
					
					
						50.0					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the contact configuration.CPWK
					 
					
						Contact Arrangement:
					
					
						1dpdt