Teilenummer 7022BBT

Relay-switch

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
7022bbt
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
006021383

Informationen zum Teil
Off-delay operation, calibrated timing head, factory installed spdt auxiliary switch kit

NSN
Nationale Bestandsnummer:
5999-00-602-1383 5999006021383
TXT
Beschreibung:
Relay-switch
INC
INC
Artikelname-Code:
00448
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
2.830 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.760 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.570 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Relay
MRC:
The quantity and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the item.AFTL
Contact Form Arrangement:
2c
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four tapped holes on back panel
MRC:
Indicates the type of action provided.AMWM
Action Type:
Time delay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Time delay
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
240.0
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
The maximum amount of current for which the item is designed,expressed in amperes.APGX
Maximum Current Rating In Amps:
20.0 resistive
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
240.0 volts
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Ac
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 204.0 and 264.0
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
10.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
1dpdt
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,that make up the switching structure of the switch.APLR
Err Default:
Err default
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,that make up the switching structure of the switch.APLR
Switch Contact Form Arrangement:
2c
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
240.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
20.0 amperes resistive
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
240.0
MRC:
The alternating current voltage of the continuous load.APLZ
Err Default:
Err default
MRC:
The alternating current voltage of the continuous load.APLZ
Continuous Load Ac Voltage:
240.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the item is rated.APMA
Err Default:
Err default
MRC:
The number of complete cyclic changes,per unit of time,for which the item is rated.APMA
Continuous Load Frequency Rating:
60.0 hertz
MRC:
The alternating current rating of the continuous load.APMB
Err Default:
Err default
MRC:
The alternating current rating of the continuous load.APMB
Continuous Load Ac Current Rating:
10.0 amperes
MRC:
The amount of time required for tripping the item,expressed in seconds.APMG
Tripping Time In Seconds:
5.0
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Err Default:
Err default
MRC:
The continuous load percentage for the specified tripping time of the item.APMH
Continuous Load Percentage Per Specificationified Tripping Action Time:
50.0
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
1dpdt