Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Delay Line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The measurement between specified points of the slot,in distinction from height.AAZT
Slot Depth:
0.062 inches
MRC:
The distance,measured along a straight line perpendicular to the longitudinal axis of the slot,from one edge to the other.ABGC
Slot Width:
0.031 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.094 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.120 inches
MRC:
The number of fixed or adjustable facilities provided to adjust an item.ACZT
Adjustment Device Quantity:
1
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Shaft
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.250 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.350 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, slotted
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
1.800 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
0.300 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Any acceptable
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Any acceptable
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
200.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
200.000 ohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
27000.0 kilohertz
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.750 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Terminal
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting provision(s).BBBW
Mounting Provision Arrangement Style:
Four position rectangular
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
0.500
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Inductance
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Variable
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
1.500 nanoseconds single section and 50.000 nanoseconds single section
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
13.0 nanoseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
4 pin
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Except testing, multiapplication