Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
714-1666-010
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Thermal Resistor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
2.000 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.050 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.025 inches
MRC:
The maximum amount of electrical energy that can be expended by an item.AEHX
Maximum Power Dissipation Rating:
2.00 milliwatts
MRC:
The time required for the temperature of an item to change 63.2 percent of the difference between its initial and final body temperature when subjected to a temperature change under zero power conditions,expressed in seconds.AEJA
Thermal Time Constant In Seconds:
6.0
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
Zero Power Resistance:
1.350 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
Zero Power Resistance Tolerance In Percent At Reference Temp:
-1.0/+1.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Disk
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
13499-714-1666 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab, solder lug