Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Variable Attenuator				
			 
			
							
										
					
						MRC:
						The primary application for which the item is designed.AAFS
					 
					
						Application Design:
					
					
						Transmission line					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Coaxial type					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 6.875 inches and 7.000 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						2.250 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						4.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.940 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						Between 5.438 inches and 5.562 inches 					
				 
							
					
						MRC:
						Equal or unequal distances between graduations representing values of measurement on a scale.ABWF
					 
					
						Scale Linearity:
					
					
						Nonlinear					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.50					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						N					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						2.0 watts peak					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						The mathematical relationship of power available at the load before and after addition of the item to the circuit,set to its lowest value of attenuation,expressed in maximum decibels.ASYC
					 
					
						Insertion Loss At Minimum Attenuation In Maximum Decibels:
					
					
						0.8					
				 
							
					
						MRC:
						The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
					 
					
						Overall Attenuation Range In Decibels:
					
					
						+0.5/+10.0					
				 
							
					
						MRC:
						The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
					 
					
						Attenuation Variation Method:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						3 threaded stud					
				 
							
					
						MRC:
						The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
					 
					
						Frequency Range:
					
					
						Between 0.000 hertz and 1.000 gigahertz 					
				 
							
					
						MRC:
						The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
					 
					
						Overall Attenuation Accuracy In Decibels:
					
					
						-0.20/+0.20					
				 
							
					
						MRC:
						The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
					 
					
						Mounting Thread Quantity:
					
					
						32 per inch					
				 
							
					
						MRC:
						Indicates the type and number of facilities for adjusting the item.CQTQ
					 
					
						Adjustment Device Type And Quantity:
					
					
						1 knob					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
					 
					
						Mounting Facility Screw Thread Diameter:
					
					
						0.190 inches					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
					 
					
						Impedance Rating In Ohms:
					
					
						50.0 input-output					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						1 connector,  coaxial,  male and 1 connector,  coaxial,  female