Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electronic Chopper				
			 
			
										
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Pin					
				 
							
					
						MRC:
						The provision/s/ for mounting the item.ABDR
					 
					
						Mounting Provision:
					
					
						Terminals					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						Between 1.219 inches and 1.281 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						Between 2.719 inches and 2.781 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						Between 0.969 inches and 1.031 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-65.0/+100.0 degrees celsius					
				 
							
					
						MRC:
						A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
					 
					
						Cubic Measure:
					
					
						3.672 cubic inches					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						1					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the contact configuration.APFR
					 
					
						Contact Arrangement:
					
					
						Single pole,  double throw					
				 
							
					
						MRC:
						Indicates the type of unit.APQB
					 
					
						Unit Type:
					
					
						Electromechanical					
				 
							
					
						MRC:
						Indicates the type of base furnished with the item.AWET
					 
					
						Base Type:
					
					
						Standard base					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Terminal					
				 
							
					
						MRC:
						An indication of whether or not a hermetically sealed feature is provided.AXNN
					 
					
						Hermetically Sealed Feature:
					
					
						Not provided					
				 
							
					
						MRC:
						An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
					 
					
						Drive Voltage Relationship To Input Voltage:
					
					
						Unequal					
				 
							
					
						MRC:
						The value,or range of values,for which the drive is rated.BGRC
					 
					
						Drive Voltage Rating:
					
					
						6.3 ac pounds per hour wet					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the drive is rated.BGRG
					 
					
						Drive Frequency Rating:
					
					
						60.0 hertz 					
				 
							
					
						MRC:
						An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
					 
					
						Contact Operation Sequence:
					
					
						Breaks before makes					
				 
							
					
						MRC:
						The value,or range of values,for which the contact is rated.BGRL
					 
					
						Contact Voltage Rating:
					
					
						10.0 dc pounds per hour wet					
				 
							
					
						MRC:
						The amount of current for which the contact is rated.BGRM
					 
					
						Contact Current Rating:
					
					
						1.0 milliamperes 					
				 
							
					
						MRC:
						The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
					 
					
						Phase Angle In Deg:
					
					
						18.0					
				 
							
					
						MRC:
						That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
					 
					
						Dwell Time Rating In Deg:
					
					
						Between 159.0 and 187.0 					
				 
							
					
						MRC:
						An indication of whether or not a feature for plug in mounting is provided.BGRS
					 
					
						Plug In Mounting Feature:
					
					
						Provided					
				 
							
					
						MRC:
						The size designation of the mounting base as it is commercially known and/or identified.BGRT
					 
					
						Base Mounting Size Designation:
					
					
						Noval tube base size					
				 
							
					
						MRC:
						Indicates the connection location.BGRY
					 
					
						Connection Location:
					
					
						Top