Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Variable Attenuator				
			 
			
										
					
						MRC:
						The primary application for which the item is designed.AAFS
					 
					
						Application Design:
					
					
						Waveguide					
				 
							
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Copper					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.625 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.625 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.125 inches 					
				 
							
					
						MRC:
						The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
					 
					
						Voltage Standing Wave Ratio:
					
					
						1.45					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						1.0 watts average					
				 
							
					
						MRC:
						The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
					 
					
						Overall Attenuation Range In Decibels:
					
					
						+0.8/+38.0					
				 
							
					
						MRC:
						The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
					 
					
						Attenuation Variation Method:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 unthreaded hole					
				 
							
					
						MRC:
						The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
					 
					
						Frequency Range:
					
					
						Between 8.200 megahertz and 12.400 megahertz 					
				 
							
					
						MRC:
						The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
					 
					
						Overall Attenuation Accuracy In Decibels:
					
					
						-0.186/+0.186					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 binding post