Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Audio Frequency Transformer				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
					 
					
						Impedance Rating In Ohms:
					
					
						1500.0  single component 2nd secondary					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
					 
					
						Impedance Rating In Ohms:
					
					
						20000.0  single component single primary and 30000.0  single component single primary					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
					 
					
						Impedance Rating In Ohms:
					
					
						1000.0  single component 1st secondary					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						300.0 hertz  single component and 100.0 kilohertz  single component					
				 
							
					
						MRC:
						The maximum amount of power for which the transformer is rated.ACZF
					 
					
						Maximum Transformer Power Rating:
					
					
						50.0 milliwatts single component					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						0.469 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
					 
					
						Body Outside Diameter:
					
					
						0.344 inches 					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						105.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Terminal single group					
				 
							
					
						MRC:
						The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
					 
					
						Winding Function And Quantity:
					
					
						1 primary single component and 2 secondary single component					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						0.5 milliamperes dc  single component single primary					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						7 wire lead