Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						749-4501-000					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Non Wire Wound Variable Resistor				
			 
			
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical bushing mounted					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						0.875 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.125 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.625 inches 					
				 
							
					
					
						Mounting Bushing Length:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						0.688 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round,  slotted					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
					 
					
						Effective Electrical Rotation In Deg Angular Rotation:
					
					
						300.0 					
				 
							
					
						MRC:
						Indicates the location of a mechanical device which prevents the turning of the item on its mounted surface,expressed by the twelve hour clock designation.AEFN
					 
					
						Nonturn Device Location:
					
					
						At 6 oclock					
				 
							
					
						MRC:
						The linear measurement of the distance from the actuator centerline to the centerline of the nonturn device.AEFP
					 
					
						Nonturn Device Radius:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.AJYN
					 
					
						Screw Thread Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
					 
					
						Screw Thread Series Designator:
					
					
						Unef					
				 
							
					
						MRC:
						The number of screw threads on the item per linear inch measured on a line parallel to the thread axis,including incomplete threads.AJYQ
					 
					
						Screw Thready Qty Per Inch (tpi):
					
					
						32.0					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						Radially positioned over less than half the circumference					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Locking bushing					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Shaft locking device					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						1.000 kilohms single section					
				 
							
					
						MRC:
						The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
					 
					
						Rotary Actuator Travel In Angular Deg:
					
					
						300.0 					
				 
							
					
						MRC:
						The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
					
					
						340.0 single section					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
					 
					
						Power Dissipation Rating Per Section In Watts:
					
					
						12.5 free air single section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-10.0/+10.0 single section					
				 
							
					
						MRC:
						The feature that controls the actuator travel.CRSX
					 
					
						Actuator Travel Control Feature:
					
					
						Stops					
				 
							
					
						MRC:
						The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
					
					
						25.0 single section					
				 
							
					
						MRC:
						The rate of change and distribution of resistance per section,in relation to the rotation of the control shaft,which establishes a standard taper curve designated by an alphabetic character and accepted for common usage.CSDL
					 
					
						Standard Taper Curve Per Section:
					
					
						A single section					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 tab,  solder lug