Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
766h
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
003305872
NSN
Nationale Bestandsnummer:
6625-00-330-5872 6625003305872
TXT
Beschreibung:
Oscilloscope
INC
INC
Artikelname-Code:
00357
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
13.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
110.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The means of attaching the item.AXGY
Mounting Method:
Cradle in cabinet
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-1.0/+1.0
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
10.000
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.000/+50.000 megahertz
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
1.0 volts
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single