Teilenummer 7A8A0763

Laboratory Oven

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
7a8a0763
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
012783940
NSN
Nationale Bestandsnummer:
6640-01-278-3940 6640012783940
TXT
Beschreibung:
Laboratory Oven
INC
INC
Artikelname-Code:
17096
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
33.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
26.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
20.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
1600.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Thermostat
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+0.0/+220.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
2
MRC:
An indication of whether or not the shelf(ves) is adjustable.BGZM
Shelf Adjustability:
Not adjustable
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Gravity
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Not provided
MRC:
The element,compound,or mixture of which the shelf is fabricated,excluding any surface treatment.BPYK
Shelf Material:
Aluminum
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Included
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Included
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the vacuum chamber.BQWP
Vacuum Chamberlength:
14.000 inches
MRC:
An indication of whether or not the vacuum chamber is removable.BQWR
Vacuum Chamber Removability:
Nonremovable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Ähnlich Laboratory Ovens

« Laboratory Equipment and Supplies {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken