Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Windlass
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
Furnished Items And Quantity:
1 motor controller
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
Indicates the type of chain by the fabricated shape and/or style of link.AJXY
Chain Type:
Die lock link
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The means used to operate the item.APHE
Operation Method:
Power
MRC:
An indication of the capstan spool/s/ mounting position.ATWG
Capstan Spool Mounting Position:
Vertical
MRC:
The design of the capstan spool surface.ATWJ
Capstan Spool Surface Design:
Plain
MRC:
The number of capstan spools included.ATWK
Capstan Spool Quantity:
1
MRC:
The number of whelped wheels included.ATWL
Whelped Wheel Quantity:
1
MRC:
The number of whelps included.ATWM
Err Default:
Err default
MRC:
The number of whelps included.ATWM
Whelp Quantity:
5
MRC:
The total load the item is capable of moving at selected speeds and the drum location.ATWN
Load Limit At Selected Speed And Drum Location:
6060.0 pounds second speed first drum
MRC:
The distance that the item will move per minute,per specific measurement scale.ATWP
Travel Rate Per Minute:
36.0 feet
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Manual and electric
MRC:
An indication of the shaft mounting position.ATXE
Err Default:
Err default
MRC:
An indication of the shaft mounting position.ATXE
Shaft Mounting Position:
Vertical
MRC:
The power required to start and operate the item at rated capacity.ATYG
Power Requirement Rating:
16.00 horsepower
Largest Diameter And Location:
18.000 inches first spool
Overall Length And Location:
16.000 inches first spool
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Any acceptable
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0