Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electromagnetic Relay
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.560 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.700 inches single mounting facility
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.250 inches single mounting facility
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.190 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.750 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.286 inches single mounting facility and 0.295 inches single mounting facility
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
Between 50.0 and 440.0
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
6 unthreaded hole single mounting facility
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Rectangular single mounting facility
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
120.0 amperes dc resistive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
1.5 amperes ac lamp load and 3.0 amperes dc lamp load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
MRC:
The amount of current the auxiliary contacts are rated to make or break at maximum rated voltage,with a specified load.CWGM
Auxiliary Contact Load Current Rating At Maximum Rated Voltage:
5.0 amperes ac inductive load and 5.0 amperes dc inductive load