Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						82213ov1pv1v1rd3500scc					
 
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Gas mass flow meter with digital display
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Flow Rate Indicating Meter				
			 
			
							
										
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Gas					
				 
							
					
						MRC:
						A narrative description of the type of inlet connection.ACQW
					 
					
						Inlet Connection Type:
					
					
						Threaded					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Rq-4a drone					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Tiltable digital display					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Case					
				 
							
					
						MRC:
						Indicates the type of unit.APQB
					 
					
						Unit Type:
					
					
						Mounted					
				 
							
					
						MRC:
						The number of scales on the item.APSJ
					 
					
						Scale Quantity:
					
					
						1					
				 
							
					
						MRC:
						The structural characteristic of the item.ARQS
					 
					
						Construction:
					
					
						Enclosed w/digital counter					
				 
							
					
						MRC:
						A narrative description of the type of outlet connection.ARTH
					 
					
						Outlet Connection Type:
					
					
						Threaded					
				 
							
					
						MRC:
						The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
					 
					
						Tube Material:
					
					
						Steel,  corrosion resisting					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Direct line					
				 
							
					
						MRC:
						An indication of whether or not a carrying handle is included.AXQG
					 
					
						Carrying Handle:
					
					
						Not included					
				 
							
					
						MRC:
						The minimum and maximum markings on a dial scale.BHBY
					 
					
						Dial Scale Marking Range:
					
					
						+0.0/+500.0					
				 
							
					
						MRC:
						Designates the size of the outlet connection included on the item.BHCM
					 
					
						Outlet Connection Size:
					
					
						0.250 in npt female					
				 
							
					
						MRC:
						An indication of whether or not a base(s) is included.BHJT
					 
					
						Base:
					
					
						Not included					
				 
							
					
						MRC:
						The maximum working pressure at which an item is designed to operate.BPHD
					 
					
						Maximum Working Pressure:
					
					
						150.0 pounds per square inch					
				 
							
					
						MRC:
						Designates the size of the inlet connection included on the item.CPZD
					 
					
						Inlet Connection Size:
					
					
						0.250 in npt female					
				 
							
					
						MRC:
						The number of metering tubes provided.CPZF
					 
					
						Metering Tube Quantity:
					
					
						1					
				 
							
					
						MRC:
						An indication of whether or not a dial scale reference pointer is included.CPZK
					 
					
						Dial Scale Reference Pointer:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a spinning float is included.CPZM
					 
					
						Spinning Float:
					
					
						Not included					
				 
							
					
						MRC:
						The inlet connection position for which the item is designed.CPZP
					 
					
						Inlet Connection Position For Which Designed:
					
					
						Horizontal					
				 
							
					
						MRC:
						The outlet connection position for which the item is designed.CPZR
					 
					
						Outlet Connection Position For Which Designed:
					
					
						Horizontal					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						12-15vdc 100milliamp max;  viton elastomers;  0-5vdc linear output;  3ft display cable length					
				 
							
					
						MRC:
						Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
					 
					
						Functional Description:
					
					
						Designed to replace volumetric flow rate devices for measuring up to 500 scc flow rate