Teilenummer 8290-J10

Electric Water Bath

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
8290-j10
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010693285

Informationen zum Teil
Shaking range 0-350 excursions/min

NSN
Nationale Bestandsnummer:
6640-01-069-3285 6640010693285
TXT
Beschreibung:
Electric Water Bath
INC
INC
Artikelname-Code:
20327
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
12.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
24.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
14.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
11.250 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
17.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
7.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+21.0/+80.0 degrees celsius
MRC:
An indication of whether or not the item is furnished with a handle.AFYG
Handle:
Not furnished
MRC:
An indication of whether or not an insulated feature is included.AHGR
Insulated Feature:
Not included
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts
MRC:
Indicates the type of heating element current whether alternating,direct,or both.BBJZ
Heating Element Current Type:
Ac
MRC:
The number of alternating current phases for which the heating element is designed.BBKB
Heating Element Phase:
Single
MRC:
The rated power the heating element can safely consume or provide,measured in watts.BBTG
Heating Element Wattage In Watts:
1000.0
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
1.6 kilowatts
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Electric immersion
MRC:
The number of heating elements provided on the item.BKGK
Heating Element Quantity:
1
MRC:
The voltage value for which the heating element is rated.BKGR
Heating Element Voltage Rating:
115.0 volts
MRC:
The element,compound,or mixture of which the reservoir is fabricated,excluding any surface treatment.BNDF
Reservoir Material:
Steel, stainless
MRC:
An indication of whether or not the reservoir is removable.BNDG
Reservoir Removability:
Nonremovable
MRC:
An indication of whether or not a constant water level attachment is included.BNDH
Constant Water Level Attachment:
Included
MRC:
An indication of whether or not a test tube rack is included.BNDM
Test Tube Rack:
Included
MRC:
The number of complete cyclic changes,per unit of time,for which the heating element is rated.BNDP
Heating Element Frequency Rating:
60.0 hertz
MRC:
An indication of whether or not an agitator is included.BNDQ
Agitator:
Included
MRC:
An indication of whether or not a thermoregulator is included.BNDR
Thermoregulator:
Included
MRC:
The range of accuracy for which the item is designed.BNDS
Accuracy Range:
-0.5/+0.5 degrees celsius
MRC:
An indication of the temperature regulating settings of the item.BNDT
Tempurature Regulating Settings:
Low; medium; high
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Not included
MRC:
An indication of whether or not a thermometer opening is provided.BNDX
Thermometer Opening:
Not provided
MRC:
An indication of whether or not a pilot light is included.BNDY
Pilot Light:
Included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement of the longest dimension of an item,in distinction from width.LGTH
Length:
14.000 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, stainless
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The physical configuration of the item.SHPE
Shape:
Rectangular
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.WDTH
Width:
10.000 inches

Ähnlich Electric Water Bathes

« Laboratory Equipment and Supplies {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken