Teilenummer 830-1319

Flow Rate Indicating Meter

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
830-1319
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
008990795
NSN
Nationale Bestandsnummer:
6680-00-899-0795 6680008990795
TXT
Beschreibung:
Flow Rate Indicating Meter
INC
INC
Artikelname-Code:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.750 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Argon
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Included
MRC:
Indicates the design type of the item.APGF
Design Type:
Glass
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Cu ft per hr; cu ft per hr
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Direct capacity reading
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
Indicates the location of the unit.AYTM
Unit Location:
Lower center front
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+4.0/+30.0
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
9/16 in. Ips
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, corrosion resisting
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
9/16 in. Ips
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The smallest increment of graduation on the dial scale.CPZJ
Dial Scale Smallest Increment:
1 cu ft; 1 cu ft
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Not included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Vertical
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Vertical
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included

Ähnlich Flow Rate Indicating Meters

« Liquid and Gas Flow, Liquid Level and Mechanical Motion Measuring Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken