Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						8350b-907-83595a-002-83572a-001-					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Front handles
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Sweep Generator				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						16.750 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.250 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						16.600 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						General purpose					
				 
							
					
						MRC:
						The number of individual sections included in the item.AFBH
					 
					
						Individual Section Quantity:
					
					
						2					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0 to 55.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The means by which the item is operated or controlled.ALBM
					 
					
						Operating Control Method:
					
					
						Automatic or manual					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Top of cabinet/counter					
				 
							
					
						MRC:
						Indicates the type of control.AQZF
					 
					
						Control Type:
					
					
						Local					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						0.01 gigahertz  1st output channel and 2.40 gigahertz  1st output channel					
				 
							
					
						MRC:
						Indicates the type of frequency adjustment included in the item.BHTD
					 
					
						Frequency Adjustment Type:
					
					
						Continuous					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						6.0 milliwatts output					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						Output channel sweep					
				 
							
					
						MRC:
						The physical configuration of the output wave.BJBJ
					 
					
						Output Wave Shape:
					
					
						Sawtooth					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						50.0  single voltage and 60.0  single voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						100.0  single voltage and 240.0  single voltage					
				 
							
					
						MRC:
						A reference number exceeding 32 positions.ELRN
					 
					
						Extra Long Reference Number:
					
					
						8350b-907-83595a-002-83572a-001-006-11869a					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As differentiated by extra long reference number