Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Toggle Switch
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mount
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.344 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.156 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.688 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Rectangular
Actuator Height:
0.641 inches
MRC:
A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
Actuator Width:
0.203 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Left position maintained and right position maintained
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
White single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
250.0 ac and 250.0 dc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.469 inches
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 pole, double throw, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
3.000 amperes resistive dc and 3.000 amperes resistive ac
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Uns
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug