Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Weapon system essential. Features - stops on section 1, 5 v lamp per section.
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Code Indicating Wheel Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.510 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.690 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.150 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.100 inches single mounting facility
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
5
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
3.440 inches single mounting facility
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
0.900 inches single mounting facility
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-62.0/+95.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F/a-18 hornet, s-3b viking, c-130f hercules, f-4 phantom, f4s, f-14 tomcat, e-2c hawkeye aircraft. Apx-76 airborne radar. Sh-60b lamps mark iii helicopter.
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket single mounting facility and unthreaded hole single mounting facility
MRC:
Indicates the type of actuator provided.AYDW
Actuator Type:
Thumbwheel all actuators
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
125.0 ac at altitude
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
125.0 ac at sea level
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular single mounting facility
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
6 1st actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
8 2nd actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
8 3rd actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
8 4th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
8 5th actuator
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Printed circuit
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
60.0 milliamperes resistive load ac at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
60.0 milliamperes resistive load highest ac voltage rating at sea level
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7 2nd section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7 3rd section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7 4th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7 5th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
1, 2, 3, 4, 4a, 4b 1st section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 8 positions 2nd section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 8 positions 3rd section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 8 positions 4th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 8 positions 5th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Decimal, 1 pole - 8 positions 1st section
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black each indicator background
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black single body
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Red each lamp
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White each indicator marking
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular inline indicating