Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Sweep Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.625 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.562 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
0-294a/m-80058
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.0 kilohertz operating channel
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
100.000 ohms output channel
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
30.000 microseconds operating channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
50.000 microseconds operating channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel pulse
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Sawtooth
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
150.0 4th voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
250.0 2nd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
320.0 1st voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-250.0 3rd voltage err-100
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
6.3 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single