Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Operating temp m10 degrees c-p50 degrees c; weighs 4.5 lbs w/o case & probe; probe is 13.0 in. Lg including 2.125 in. Cup & has 4 ft. Lg cable
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Field Strength Meter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
4.500 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.625 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
20 single indicator 2nd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
30 single indicator 1st range
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Handle 1; rechargeable ni cad batteries 2; shielded, foam-lined carrying case designed to hold up to 4 probes; manual; ac line cord; 8723 type probe
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.300/+40.000 gigahertz
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
30.0 decibels
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator all ranges
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator all ranges
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.2/+20.0 milliwatts per square centimeter single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+1.0/+100.0 milliwatts per square centimeter single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+2.0/+200.0 milliwatts per square centimeter single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+20.0/+2000.0 milliwatts per square centimeter single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+3.0/+10.0 decibels single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+3.0/+300.0 inches single indicator 2nd range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Internal battery accommodation and portable and warning feature and zero adjuster
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 110.0 ac and 220.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Performs measurements iaw/ansi & fcc recommendations for radiation monitoring test equipment
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Hand-held