Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Digital display
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Multimeter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						12.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						9.000 inches 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 50.000 hertz and 60.000 hertz 					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
					 
					
						Furnished Items And Quantity:
					
					
						Rack mounting kit					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Rack					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						External					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+1200.0 volts,  ac single indicator 11th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 kilohms single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 volts,  ac single indicator 8th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 megohms single indicator 5th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 kilohms single indicator 2nd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 volts,  ac single indicator 9th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 kilohms single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 volts,  ac single indicator 10th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 ohms single indicator 7th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2000.0 kilohms single indicator 4th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						-1200.0/+1200.0 volts,  dc single indicator 15th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						-2.0/+2.0 volts,  dc single indicator 12th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						-20.0/+20.0 volts,  dc single indicator 13th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						-200.0/+200.0 millivolts,  dc single indicator 6th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						-200.0/+200.0 volts,  dc single indicator 14th range					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Switch					
				 
							
					
						MRC:
						The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
					 
					
						Operating Voltage Rating In Volts:
					
					
						Between 110.0 ac and 230.0 ac 					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						D1 rectangular or square