Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Liquid Quantity Transmitter				
			 
			
										
					
						MRC:
						The means by which the item is actuated.AFLW
					 
					
						Actuation Method:
					
					
						Float					
				 
							
					
						MRC:
						The number of mechanical connections provided.ASSB
					 
					
						Mechanical Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
					 
					
						Mechanical Connection Size:
					
					
						1in					
				 
							
					
						MRC:
						Indicates the type of mechanical connection/s/ provided.ASSD
					 
					
						Mechanical Connection Type:
					
					
						Flange					
				 
							
					
						MRC:
						The pressure at which an item is designed to operate.BGST
					 
					
						Pressure Rating:
					
					
						150.000 pounds per square inch 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
					 
					
						Float Material:
					
					
						Steel,  stainless					
				 
							
					
						MRC:
						The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
					 
					
						Criticality Code Justification:
					
					
						Zzzy					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Interface					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						Magnetic permeability shall not exceed 2.0 after fabrication