Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Flow Rate Indicating Meter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						9.500 inches 					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Nitrogen gas					
				 
							
					
						MRC:
						A narrative description of the type of inlet connection.ACQW
					 
					
						Inlet Connection Type:
					
					
						Threaded					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
					 
					
						Inlet Bolt Circle Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						An indication of whether or not an integral safety device is included.AHZU
					 
					
						Integral Relief Valve:
					
					
						Not included					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Ball float					
				 
							
					
						MRC:
						An indication of the type of meter.ANTH
					 
					
						Meter Type:
					
					
						Float					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Case					
				 
							
					
						MRC:
						The number of scales on the item.APSJ
					 
					
						Scale Quantity:
					
					
						1					
				 
							
					
						MRC:
						The structural characteristic of the item.ARQS
					 
					
						Construction:
					
					
						Inclosed w/sight window					
				 
							
					
						MRC:
						A narrative description of the type of outlet connection.ARTH
					 
					
						Outlet Connection Type:
					
					
						Threaded					
				 
							
					
						MRC:
						Indicates the type of scale.ATEQ
					 
					
						Scale Type:
					
					
						Millimeter reference reading					
				 
							
					
						MRC:
						The number of floats provided.AWAE
					 
					
						Float Quantity:
					
					
						1					
				 
							
					
						MRC:
						The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
					 
					
						Tube Material:
					
					
						Glass					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Direct line					
				 
							
					
						MRC:
						An indication of whether or not a carrying handle is included.AXQG
					 
					
						Carrying Handle:
					
					
						Not included					
				 
							
					
						MRC:
						Designates the size of the outlet connection included on the item.BHCM
					 
					
						Outlet Connection Size:
					
					
						0.250 in.-18 npt					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
					 
					
						Outlet Bolt Circle Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						An indication of whether or not a base(s) is included.BHJT
					 
					
						Base:
					
					
						Not included					
				 
							
					
						MRC:
						Indicates the type of float used.BHSQ
					 
					
						Float Type:
					
					
						Guided					
				 
							
					
						MRC:
						Indicates the type of guide provided.BMHW
					 
					
						Guide Type:
					
					
						Hollow tapered rod					
				 
							
					
						MRC:
						An indication of whether or not an integral heat source is included.BNHN
					 
					
						Integral Heat Source:
					
					
						Not included					
				 
							
					
						MRC:
						The maximum working pressure at which an item is designed to operate.BPHD
					 
					
						Maximum Working Pressure:
					
					
						160.0 pounds per square inch					
				 
							
					
						MRC:
						Designates the size of the inlet connection included on the item.CPZD
					 
					
						Inlet Connection Size:
					
					
						0.250 in.-18 npt					
				 
							
					
						MRC:
						The number of metering tubes provided.CPZF
					 
					
						Metering Tube Quantity:
					
					
						1					
				 
							
					
						MRC:
						An indication of whether or not a dial scale reference pointer is included.CPZK
					 
					
						Dial Scale Reference Pointer:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a spinning float is included.CPZM
					 
					
						Spinning Float:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not an integral pulsation dampener is included.CPZN
					 
					
						Integral Pulsation Dampener:
					
					
						Not included					
				 
							
					
						MRC:
						The inlet connection position for which the item is designed.CPZP
					 
					
						Inlet Connection Position For Which Designed:
					
					
						Vertical					
				 
							
					
						MRC:
						Indicates the type of inlet connection device provided.CPZQ
					 
					
						Inlet Connection Device Type:
					
					
						Stationary					
				 
							
					
						MRC:
						The outlet connection position for which the item is designed.CPZR
					 
					
						Outlet Connection Position For Which Designed:
					
					
						Vertical					
				 
							
					
						MRC:
						Indicates the type of outlet connection device provided.CPZS
					 
					
						Outlet Connection Device Type:
					
					
						Stationary					
				 
							
					
						MRC:
						An indication of whether or not an alarm signal is included.CPZT
					 
					
						Alarm Signal:
					
					
						Not included