Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Volumetric Positive Displa Meter
MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
225.0 pounds per square inch
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Drilled flange
MRC:
A measurement of the smallest dimension of an inlet flange,in distinction from length or width.ACRF
Inlet Flange Thickness:
0.380 inches
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
3
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.562 inches
MRC:
The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
Inlet Bolt Circle Diameter:
2.438 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
250.0 degrees fahrenheit
MRC:
Designates the size of the inlet connection included on the item.ANHY
Inlet Connection Size:
0.500 in. Ips
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Drilled flange
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Disk
MRC:
The volume of liquid flowing through the item in a given period of time.BHCC
Liquid Flow Rate:
Between 3.0 gallons per minute and 30.0 gallons per minute
MRC:
Indicates the type of register provided on the item.BHCG
Register Type:
Any acceptable
MRC:
An indication of whether or not the inlet is provided with a union connection.BHCL
Inlet Union Connection:
Not provided
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
0.500 in. 1ps
MRC:
A measurement of the smallest dimension of an outlet flange,in distinction from length or width.BHCR
Outlet Flange Thickness:
0.380 inches
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
2.438 inches
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.562 inches
MRC:
An indication of whether or not the outlet is provided with a union connection.BHCX
Outlet Union Connection:
Not provided