Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
904-122
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
010193371

Informationen zum Teil
End window

NSN
Nationale Bestandsnummer:
6665-01-019-3371 6665010193371
TXT
Beschreibung:
Radiacmeter
INC
INC
Artikelname-Code:
07833
INC
COM
Beachtung:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Solid state
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.125/+12.500 milliroentgens
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-10.0/+10.0 all ranges
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
7.5 dc
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
7.5