Recovery time 1 to 2 min; int valve controlled lub; shipping wt 135 lbs; comes equipped w/ 1/2 hp mtr w/ pulley & v-belt, belt guard, sight oil level ga, draincock & manual; initial supply + 1 ex qt oil is furn
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Rotary Vacuum Pump
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.500
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Unthreaded external
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Any acceptable
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a body surface.ABEM
Body Surface Treatment:
Any acceptable
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
15.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.750 inches
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Oil
MRC:
The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.ADLE
Vacuum Rating:
0.1 millitorr
MRC:
The element,compound,or mixture of which the pump body is fabricated,excluding any surface treatment.AENE
Pump Body Material:
Any acceptable
MRC:
The specific gas with which the item is designed to be used.AENF
Specific Gas For Which Designed:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Any acceptable
MRC:
The length of a straight line which passes through the center of the intake connection,and terminates at the outside circumference.AENM
Intake Connection Outside Diameter:
1.220 inches
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
525.0
MRC:
The device which prevents or reduces the amount of condensable vapors from entering and contaminating the item.AEQG
Vapor Condensation Preventative Device:
Gas ballast valving
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
4.9 cubic feet per minute in free air
MRC:
An indication of the system for which the item is designed.AERP
System Design:
Noncorrosive