Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Otoscope & ophthalmoscope set oper btry pwr w/case
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Otoscope And Ophthalmoscope Set
MRC:
The number of lamps included with the item.AEWR
Lamp Quantity:
1
MRC:
The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
Err Default:
Err default
MRC:
The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
Lamp Candlepower Rating In Footcandles:
300.0
MRC:
The voltage for which the lamp is rated for normal operation,expressed in volts.AEWX
Lamp Voltage Rating In Volts:
2.5
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Provided
MRC:
The number of lampholders included on the item.AHGF
Lampholder Quantity:
1
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Ophthalmoscope head lamp, 1; otoscope head lamp, 1
MRC:
The means used to operate the item.APHE
Operation Method:
Electrical
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Battery
MRC:
Designates the size of the battery handle(s).CBTC
Err Default:
Err default
MRC:
Designates the size of the battery handle(s).CBTC
Battery Handle Size:
Medium
MRC:
The number of speculums provided with the item.CBTY
Speculum Quantity:
1 and 1 and 1 and 1 and 10
MRC:
The amount of current for which the lamp is rated.CBWC
Lamp Current Rating:
200.0 milliamperes
MRC:
Indicates the type of otoscope head provided.CMWP
Err Default:
Err default
MRC:
Indicates the type of otoscope head provided.CMWP
Otoscope Head Type:
Closed
MRC:
Indicates the type of speculum provided.CMWY
Speculum Type:
Aural and aural and aural and aural and optical
MRC:
The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
Err Default:
Err default and err default and err default and err default and err default
MRC:
The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
Speculum Material:
Plastic, thermoplastic and plastic, thermoplastic and plastic, thermoplastic and plastic, thermoplastic and plastic
MRC:
Designates the size of the speculum.CMXB
Err Default:
Err default and err default and err default and err default and err default
MRC:
Designates the size of the speculum.CMXB
Speculum Size:
2 millimeter and 3 millimeter and 4 millimeter and 5 millimeter and adult
MRC:
The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
Err Default:
Err default
MRC:
The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
Ophthalmoscope Head Design Designation:
May
MRC:
The number of lampholders included on the ophthalmoscope head.CMXD
Err Default:
Err default
MRC:
The number of lampholders included on the ophthalmoscope head.CMXD
Ophthalmoscope Head Lampholder Quantity:
1
MRC:
The number of lamps included with the ophthalmoscope head.CMXF
Err Default:
Err default
MRC:
The number of lamps included with the ophthalmoscope head.CMXF
Ophthalmoscope Head Lamp Quantity:
1
MRC:
The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
Err Default:
Err default
MRC:
The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
Ophthalmoscope Head Lamp Voltage Rating In Volts:
2.5
MRC:
The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
Err Default:
Err default
MRC:
The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
Ophthalmoscope Head Lamp Current Rating:
190.0 milliamperes
MRC:
The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
Err Default:
Err default
MRC:
The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
Ophthalmoscope Head Lamp Candlepower Rating In Footcandles:
3.5
MRC:
The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
Err Default:
Err default
MRC:
The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
Ophthalmoscope Head Lens Negative Range In Diopters:
-20.0/-1.0
MRC:
The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
Err Default:
Err default
MRC:
The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
Ophthalmoscope Head Lens Positive Range In Diopters:
+0.5 to 20.0
MRC:
An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
Err Default:
Err default
MRC:
An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
Ophthalmoscope Head Lens Zero Aperture:
Included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Fiber optics; as differentiated by the furnished items and quantity requirements