Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.978 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.700 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.750 inches
MRC:
The commercial and government entity (cage) code of the government agency,industrial organization,or other source,which controls the document.AJJY
Document Source:
11352
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
20.0 single power output
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
28.0 dc pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
1500.0 dc volts single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+100.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Reverse voltage protection
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
4.0 dc amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
9.0 volts peak single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
3 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Binding post single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
400.0 dc amperes single operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Binding post single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 single operating power rqmt