Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electrical Solenoid				
			 
			
										
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2a mounting facility bushing					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical frame					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						1.312 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.500 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
					 
					
						Case Surface Treatment:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Dustproof					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the electrical connector receptacle.AEEE
					 
					
						Connector Manufacturer Code:
					
					
						77820					
				 
							
					
						MRC:
						The identifying part number assigned to the electrical connector receptacle.AEEF
					 
					
						Connector Manufacturer Part Number:
					
					
						Pt02h-8-32					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The number of magnetic coils provided.APAF
					 
					
						Magnetic Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						A measurement of the opposition to the flow of direct or alternating current.APCC
					 
					
						Electrical Resistance:
					
					
						Between 29.00 ohms and 32.00 ohms 					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						End opposite actuator					
				 
							
					
						MRC:
						The voltage rating at which the item is designed to operate,expressed in volts.ASXH
					 
					
						Voltage Rating In Volts:
					
					
						24.0 dc 					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded bushing					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						16 mounting facility bushing					
				 
							
					
						MRC:
						The movement of the actuator when force is applied.CNXT
					 
					
						Actuator Stroke Type:
					
					
						Pull					
				 
							
					
						MRC:
						The amount of linear force delivered.CNXW
					 
					
						Linear Force Delivered:
					
					
						3.25 ounces					
				 
							
					
						MRC:
						Indicates the type of means provided for connection of the power takeoff.CNXX
					 
					
						Power Takeoff Connection Type:
					
					
						Plain					
				 
							
					
						MRC:
						The maximum linear travel from the de-energized to the energized position.CNYD
					 
					
						Energizing Stroke Maximum Length:
					
					
						0.025 inches					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.375 inches mounting facility bushing					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unc mounting facility bushing					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						1 connector,  receptacle