Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Meter Movement Relay				
			 
			
										
					
						MRC:
						The number of terminals for providing electrical connection to the item.AARA
					 
					
						Terminal Quantity:
					
					
						5					
				 
							
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Wire loop					
				 
							
					
						MRC:
						The standard of valuation as represented by the inscription.ABWC
					 
					
						Scale Unit Of Measure Inscription:
					
					
						Milliamperes					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						The pattern or arrangement that describes the mounting configuration of the item.ALGC
					 
					
						Mounting Configuration:
					
					
						Three 4-40 threaded studs spaced 120 degrees apart 0n 2.440 in. Dia					
				 
							
					
						MRC:
						The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
					 
					
						Scale Measurement Range:
					
					
						+0.0/+200.0					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
					 
					
						Main Contact Arrangement:
					
					
						1 pole,  double throw,  both positions maintained					
				 
							
					
						MRC:
						Indicates the type of current used in the meter movement.APGN
					 
					
						Meter Movement Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						An indication of the minimum and maximum amount of current used in the meter movement.APGR
					 
					
						Meter Movement Current Range:
					
					
						+0.0/+200.0 milliamperes					
				 
							
					
						MRC:
						An indication of the direction of the meter movement reading range.APGT
					 
					
						Meter Movement Range Direction:
					
					
						Left to right					
				 
							
					
						MRC:
						Indicates the type of mount utilized to support the meter.APMR
					 
					
						Meter Mounting Type:
					
					
						Flush					
				 
							
					
						MRC:
						An indication of the specific condition that causes the contacts to close.APMT
					 
					
						Contact Closing Condition:
					
					
						Increase value					
				 
							
					
						MRC:
						An indication of whether or not the reset facilities are provided.APNR
					 
					
						Reset Facility Feature:
					
					
						Not provided					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
					 
					
						Mounting Flange Diameter:
					
					
						2.800 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
					 
					
						Meter Body Diameter:
					
					
						2.155 inches 					
				 
							
					
						MRC:
						A measurement between the mounting flange and the face of the item, in distinction from height.APTN
					 
					
						Meter Depth To Mounting Flange:
					
					
						2.700 inches