Teilenummer 9T56Y2938G2

Power Transformer

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
9t56y2938g2
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010216968

Informationen zum Teil
Fused secondary

NSN
Nationale Bestandsnummer:
5950-01-021-6968 5950010216968
TXT
Beschreibung:
Power Transformer
INC
INC
Artikelname-Code:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz single component and 60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 2 secondary single component
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
50.0 volts-amperes single component all secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
120.00 ac pounds per hour dry single component all primary and 240.00 ac pounds per hour with retaining chain single component all primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
120.00 ac pounds per hour dry single component all secondary and 240.00 ac pounds per hour with retaining chain single component all secondary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 terminal block w/screws

Ähnlich Power Transformers

« Coils and Transformers {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken