Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Thermostatic Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.562 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.094 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.625 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.250 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
2.125 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
32.0 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket and threaded hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
40 all threaded hole
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.125 inches all threaded hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally open, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
16.0 amperes resistive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
8.3 amperes resistive load first voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point not adjustable and actuation point not adjustable
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level first voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 first voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 second voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all threaded hole