Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Reactor-transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.437 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.437 inches
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
6.00 henry single component single winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.3 kilohertz single component and 2.5 kilohertz single component
MRC:
The ratio of the number of turns in a primary winding to the number of turns in the secondary winding of a transformer.ACZH
Primary To Secondary Turn Ratio:
1.6 to 1 single component
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole all groupings
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
50.0 milliamperes dc single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
340.000 single component single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 solder stud