Teilenummer A2060476ISSUEA

Time Totalizing Meter

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
a2060476issuea
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
009400758
NSN
Nationale Bestandsnummer:
6645-00-940-0758 6645009400758
TXT
Beschreibung:
Time Totalizing Meter
INC
INC
Artikelname-Code:
08066
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Blade/knife
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Panel
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.210 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 0.120 in; 0.130 in; maxmium dia. Mtg holes on a 1.220 in; circle radius spaced 120 deg. C to c
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Drum register
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
An indication of the unit of measure for which the item is designed.ANSX
Measurement Unit:
Hours
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
2.695 inches
MRC:
The frequency at which the item functions.APTT
Operating Frequency:
60.0 hertz
MRC:
An indication of whether or not a hermetic protection is provided.AQCS
Hermetic Protection:
Not provided