Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Engine Generator Cutout Relay				
			 
			
										
					
						MRC:
						An indication of whether or not a frame is included.ABWP
					 
					
						Frame:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Corrosion resistant					
				 
							
					
						MRC:
						The value of the current flowing through the item when operated at its designed voltage,expressed in amperes.AFSS
					 
					
						Design Current Rating In Amps:
					
					
						Between 200.0 and 400.0 					
				 
							
					
						MRC:
						An indication of whether or not an item is capable of operation while submerged.AHZV
					 
					
						Submersibility:
					
					
						Nonsubmersible					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						3					
				 
							
					
						MRC:
						An indication of whether or not shielding against radio interference is provided.ALBH
					 
					
						Radio Interference Shielding:
					
					
						Not provided					
				 
							
					
						MRC:
						Designates the size of the mounting facility.AWYX
					 
					
						Mounting Facility Size:
					
					
						1/4 in.					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Unthreaded hole					
				 
							
					
						MRC:
						The electrical voltage of the system for which the item is designed.AXHT
					 
					
						Voltage System For Which Designed:
					
					
						Between 24.0 volts and 29.0 volts 					
				 
							
					
						MRC:
						Indicates the type of ground polarity utilized.AXHX
					 
					
						Ground Polarity Type:
					
					
						Negative					
				 
							
					
						MRC:
						The cut-in voltage/s/ required to close the circuit.AXHZ
					 
					
						Cut-in Voltage Rating:
					
					
						Between 16.0 volts and 20.0 volts 					
				 
							
					
						MRC:
						The cutout voltage/s/ required to open /break/ the circuit.AXMN
					 
					
						Cutout Voltage Rating:
					
					
						Between 1.0 volts and 5.0 volts 					
				 
							
					
						MRC:
						The discharge current(s) required to open (break) the current.AXMR
					 
					
						Cutout Current Rating:
					
					
						200.0 amperes