Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Thermostatic Switch				
			 
			
										
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Weatherproof					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.453 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						4.078 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.297 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a capillary tube.AEVT
					 
					
						Capillary Tube Length:
					
					
						72.0 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bulb.AEVU
					 
					
						Bulb Length:
					
					
						3.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
					 
					
						Bulb Diameter:
					
					
						0.375 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						2.750 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the vertical plane.AFDV
					 
					
						Longest Vertical Distance Between Mounting Centers:
					
					
						3.125 inches 					
				 
							
					
						MRC:
						Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
					 
					
						Tempurature Sensing Element Type:
					
					
						Capillary tube-bulb					
				 
							
					
						MRC:
						The temperature at which the item operates.AWTN
					 
					
						Operating Tempurature Rating:
					
					
						Between -65.0 degrees fahrenheit and 150.0 degrees fahrenheit 					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket and unthreaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Electrical access port					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Increase					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Four position rectangular					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  single throw,  normally open,  momentary action					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Screw					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						24.0 amperes resistive load first voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						24.0 amperes resistive load second voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						3.0 amperes resistive load third voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						0.5 amperes resistive load fourth voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point adjustable,  preset					
				 
							
					
						MRC:
						The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
					 
					
						Contact Adjustment Range:
					
					
						-10.00/+65.00 actuation point degrees fahrenheit					
				 
							
					
						MRC:
						Indicates the type of device provided for manual adjustment of the contact(s).CTYS
					 
					
						Contact Adjustment Type:
					
					
						External actuation point screw					
				 
							
					
						MRC:
						The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
					 
					
						Contact Stimulus Rating:
					
					
						35.00 actuation point  degrees fahrenheit and 25.00 deactuation point  degrees fahrenheit					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						120.0 ac at sea level first voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						120.0 dc at sea level third voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						240.0 ac at sea level second voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						240.0 dc at sea level fourth voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Liquid					
				 
							
					
						MRC:
						An indication of the precious material and its location in the item.PMLC
					 
					
						Precious Material And Location:
					
					
						Contacts silver					
				 
							
					
						MRC:
						Identification of the precious material contained in the item.PRMT
					 
					
						Precious Material:
					
					
						Silver					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular w/bracket